<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Paramedical Sciences and Military Health</title>
<title_fa>علوم پیراپزشکی و بهداشت نظامی</title_fa>
<short_title>Paramedical Sciences and Military Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jps.ajaums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2423-7507</journal_id_issn>
<journal_id_issn_online>2538-3086</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/acadpub.JPSMH</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>یک فانتوم سر ریاضیاتی برای بررسی‌های دوزیمتری به روش مونت‌کارلو</title_fa>
	<title>A Mathematical Head Phantom for Dosimetry Measurements by Monte Carlo Method</title>
	<subject_fa>مقالات کامل</subject_fa>
	<subject>full articles</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt; به منظور رعایت اصول حفاظت پرتویی در بسیاری از پروسه&#8204;های درمانی و تشخیصی، بررسی&#8204;های دوزیمتری بر روی سیستم&#8204;هایی دوزیمتریک انجام می&#8204;شود. از روش&#8204;های محاسباتی مونت&#8204;کارلو به دلیل پیچیدگی و هزینه&#8204;ی بالای ساخت فانتوم های اختصاصی، استفاده می&#8204;شود. پیچیدگی بالای فانتوم های دیجیتالی، زمان اجرا و بار محاسباتی روش دوزیمتری مونت&#8204;کارلو را به شدت افزایش می&#8204;دهد. در بسیاری از مطالعات، همه&#8204;ی اجزا تعریف شده و دقت بالای فانتوم های دیجیتالی وکسل بندی شده لازم نیست و با مدل نمودن یک فانتوم دیجیتالی ساده می&#8204;توان به اهداف مطالعه دست یافت. با توجه به اهمیت و جایگاه فانتوم های دیجیتالی در محاسبات دوزیمتری به روش مونت&#8204;کارلو، در این مطالعه یک فانتوم سر انسان بر اساس داده&#8204;های آناتومیک سر جهت مطالعات دوزیمتریک ناحیه سر ارائه می&#8204;گردد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مواد و روش&#8204;ها:&lt;/strong&gt; در این مطالعه شبیه سازی فانتوم سر معادل انسان با استفاده از کد هسته&#8204;ای &lt;span dir=&quot;LTR&quot;&gt;MCNPx&lt;/span&gt; (ورژن &lt;span dir=&quot;LTR&quot;&gt;2.4.0&lt;/span&gt;) انجام می&#8204;گردد. فانتوم سر پیشنهاد شده در این مطالعه دارای بخش&#8204;های استخوان جمجمه، بافت مغز، چشم، لنز چشم، استخوان صورت، گردن و پوست می&#8204;باشد که با توجه به ترکیب اتمی و دانسیته گزارش شده توسط گزارش &lt;span dir=&quot;LTR&quot;&gt;ICRU 44&lt;/span&gt; و سایت انستیتو ملی استانداردها و تکنولوژی (&lt;span dir=&quot;LTR&quot;&gt;NIST&lt;/span&gt;) مدل شده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; فانتوم سر از لحاظ بصری و ویژگی&#8204;های ساختاری در نماهای مختلف توسط دو متخصص علوم تشریح به صورت جداگانه مورد بررسی قرار گرفت. درستی و مطابقت ویژگی&#8204;های ساختاری فانتوم شبیه سازی شده با سر انسان توسط هر دو متخصص تأیید گردید. فانتوم مدل شده قابل تغییر و ارتقا می&#8204;باشد و بر اساس اهداف مطالعاتی مختلف می&#8204;توان بخش&#8204;های دیگر از جمله تومور، بافت&#8204;های حیاتی و .. در آن لحاظ نمود.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;بحث و نتیجه گیری:&lt;/span&gt;&lt;/strong&gt; &lt;span dir=&quot;RTL&quot;&gt;با استفاده از فانتوم دیجیتالی ارائه شده، می&#8204;توان به بررسی&#8204;های دوزیمتری پیش کلینیکی از جمله تعیین دوز جذبی بافت&#8204;های حیاتی در کاربردهای درمانی و تشخیصی و همچنین تأثیر روش&#8204;های شیلدینگ و آرایش&#8204;های تصویربرداری مختلف در کیفیت تصویر را ارزیابی نمود.&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Introduction:&lt;/strong&gt; In diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. Monte Carlo methods are used due to the high complexity and cost of patient-specific phantom construction. The high complexity of the digitized phantoms greatly increases the time and computational task of the Monte Carlo calculation. In many studies, all of the defined components and high precision of the voxelized phantom are not necessary and the study objectives could be achieved by a simple digital phantom modeling. In this study, an anatomic-based human head phantom was modeled considering the importance of the digitized phantoms for Monte Carlo dosimetry measurements.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Methods and Materials:&lt;/strong&gt; In this study, the anthropomorphic head phantom was simulated using MCNPx (version 2.4.0). The proposed head phantom consist of the skull, brain, eyes, eye lens, facial bones, neck and skin that are modeled based on the atomic compositions and density magnitudes reported by ICRU report No. 44 and the national institute of standards and technology (NIST) reports.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; The visual and structural characteristics of the modeled head phantom in different cross-sectional views were evaluated by two scientific experts. For modeled phantom, integrity and compliance of the structural features with the actual human head were confirmed by the experts.Simulated phantom is flexible and upgradeable. According to study objectives, other tissues including tumors, the specific tissue of interest, and etc. could be added to the model.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Discussion and Conclusion:&lt;/strong&gt; Pre-clinical dosimetric studies including the determination of dose to organ at risks in the diagnostic and therapeutic situations as well as the effect of shielding methods and imaging geometries in the image quality could be evaluated using the modeled phantom.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;/p&gt;
</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Digitized phantom, Monte Carlo dosimetry, Mathematical head phantom, Anthropomorphic phantom</keyword>
	<start_page>12</start_page>
	<end_page>20</end_page>
	<web_url>http://jps.ajaums.ac.ir/browse.php?a_code=A-10-1-42&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Seyed Salman</first_name>
	<middle_name></middle_name>
	<last_name>Zakariaee</last_name>
	<suffix></suffix>
	<first_name_fa>سید سلمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ذکریایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600259</code>
	<orcid>1003194753284600259</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>AJA university of Medical Sciences</affiliation>
	<affiliation_fa>علوم پزشکی آجا</affiliation_fa>
	 </author>


	<author>
	<first_name>Valiallah</first_name>
	<middle_name></middle_name>
	<last_name>Saba</last_name>
	<suffix></suffix>
	<first_name_fa>ولی اله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صبا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600260</code>
	<orcid>1003194753284600260</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>AJA university of Medical Sciences</affiliation>
	<affiliation_fa>علوم پزشکی آجا</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>