<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Paramedical Sciences and Military Health</title>
<title_fa>علوم پیراپزشکی و بهداشت نظامی</title_fa>
<short_title>Paramedical Sciences and Military Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jps.ajaums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2423-7507</journal_id_issn>
<journal_id_issn_online>2538-3086</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/acadpub.JPSMH</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی</title_fa>
	<title>Assessment of Entrance Skin Doses and Effective Dose for Common X-ray Diagnostic Examinations</title>
	<subject_fa>مقالات کامل</subject_fa>
	<subject>full articles</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt; امروزه شاهد افزایش تصاعدی استفاده از تکنیکهای مختلف رادیولوژی در جوامع مختلف و ایران میباشیم، به طوری که روش های رادیولوژیکی یکی از عوامل تأثیر گذار در افزایش دز افراد جوامع مختلف میباشد، اندازه گیری دز دریافتی بیماران از این آزمون ها توسط سازمان های مرتبط با موضوع حفاظت پرتویی توصیه شده است. هدف از این تحقیق اندازه گیری میزان دز ورودی پوست، دز مؤثر در برخی آزمون های رایج رادیولوژی بوده است تا در راستای کاهش هرچه بیشتر دز دریافتی بیماران مورد توجه قرار گیرد.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مواد و روشها:&lt;/strong&gt; پس از بررسی آمار و جزئیات آزمون های رادیولوژی رایج مراکز تصویر برداری، در طول یک دوره 3 ماهه، هشت آزمون پرکاربرد رادیولوژی انتخاب گردید. برای 283 بیماری که تحت 8 آزمون ریه (خلفی-قدامی)، لگن (قدامی-خلفی)، شکم (قدامی-خلفی)، جمجمه (قدامی-خلفی)، مهره های سینه ای (قدامی-خلفی)، مهره های سینه ای (نمای کناری)، مهره های کمری (قدامی-خلفی)، مهره های کمری (کناری) قرار گرفته بودند کلیه شرایط پارامترهای تابش دهی (اختلاف پتانسیل، میلی آمپر ثانیه، فاصله تیوب تا گیرنده) ثبت گردید، دز ورودی پوست و دز مؤثر با استفاده از فرمول و نرم افزار محاسباتی و بر مبنای محاسبات مونت-کارلو ( PCXMC ) در یک فانتوم متوسط انسانی برآورد شد.&lt;br&gt;
&lt;strong&gt;یافته ها:&lt;/strong&gt; میانگین دز ورودی پوست (میلی گری) و دز مؤثر (میلی سیورت) بیماران در 8 آزمون ریه (خلفی-قدامی)، لگن (قدامی-خلفی)، شکم (قدامی-خلفی)، جمجمه (قدامی-خلفی)، مهره های سینه ای (قدامی-خلفی)، مهره های سینه ای (نمای کناری)، مهره های کمری (قدامی-خلفی)، مهره های کمری (کناری) به ترتیب بر حسب میلی گری و میلی سیورت برابر با ( 0/028-0/15 )، ( 0/87-5/4 )، ( 0/61-2/7 )، ( 0/05-2/2 )، ( 0/28-4/6 )، ( 0/20-5/1 )، ( 0/47-5/8 )، ( 0/30-6/2 ) محاسبه گردید.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;بحث و نتیجه گیری:&lt;/strong&gt; همان طور که انتظار می رفت دز دریافتی بیماران تغییرات زیادی داشت زیرا این مقادیر به عوامل زیادی از جمله نوع سیستم تشخیصی ، ناحیه آزمون، تجربه و مهارت اپراتور و وزن بیمار بستگی دارد. در آزمون های رادیولوژی می توان با استفاده از میدان دیدهای کوچک، اختلاف پتانسیل مناسب و میلی آمپر ثانیه مناسب دز دریافتی بیماران را کاهش داد و این نیازمند آموزشهای فردی در راستای بهینه سازی دز دریافتی بیماران میباشد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Introduction:&lt;/strong&gt; Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&amp;rsquo;s radiation protection. Thus, the related radiation-protection organizations have recommended measuring the patient doses resulted from such techniques. The main purpose of this study was to investigate the patient doses in common radiographic examinations.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Methods and Materials:&lt;/strong&gt; The eight most commonly radiology examinations were selected for dosimetry calculations after reviewing and analyzing radiology examination data at an imaging center over a 3-month period. 283 patients underwent eight radiography procedures containing Chest (PA), Pelvice (AP), Abdomen (AP), Skull (AP), Thoracic Spine (AP), Thoracic Spine (LAT), Lumbar Spine (AP) and, Lumbar Spine (LAT) were selected for dose measurements. Data of exposure parameters (kVp, mAs, FFD and projection) were collected in all 283 patients. ESD (Entrance Skin Dose) and effective dose values were calculated using the analytical formula and a software indirectly (PCXMC). In addition, they compared with published works and internationally established diagnostic reference levels.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; The average entrance skin dose (in mGy) and effective dose (in mSv) for the Chest (PA), Pelvice (AP), Abdomen (AP), Skull (AP), Thoracic Spine (AP), Thoracic Spine (LAT), Lumbar Spine (AP) and, Lumbar Spine (LAT) were (0.15-0.028), (5.4-0.87), (2.7-0.61), (2.2-0.05), (4.6-0.28), (5.1-0.20), (5.8-0.47), (6.2-0.30), respectively.&lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Discussion and Conclusion:&lt;/strong&gt; As expected, the patient doses in radiology exams varied consumedly because it depends on many factors including the type of medical imaging systems, examination complexity, experience and skill of the operator, and patient&amp;rsquo;s weight. In radiology, it is possible to reduce patients&amp;rsquo; effective dose using small field of views, appropriate potential difference and mAs. There is still a need for personnel training and national guidance on good&lt;br&gt;
practice for optimizing of patients&amp;rsquo; doses.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>آزمو نهای رادیولوژی, دز پوستی, دز مؤثر</keyword_fa>
	<keyword>Radiology examination, Effective dose, Entrance skin dose</keyword>
	<start_page>1</start_page>
	<end_page>5</end_page>
	<web_url>http://jps.ajaums.ac.ir/browse.php?a_code=A-10-1-41&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Salar</first_name>
	<middle_name></middle_name>
	<last_name>Bijari</last_name>
	<suffix></suffix>
	<first_name_fa>سالار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیجاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600276</code>
	<orcid>1003194753284600276</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Amin</first_name>
	<middle_name></middle_name>
	<last_name>Banaei</last_name>
	<suffix></suffix>
	<first_name_fa>امین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بنایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>aminabsp@gmail.com</email>
	<code>1003194753284600277</code>
	<orcid>1003194753284600277</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Majid</first_name>
	<middle_name></middle_name>
	<last_name>Kanani</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کنعانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600278</code>
	<orcid>1003194753284600278</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
