<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Paramedical Sciences and Military Health</title>
<title_fa>علوم پیراپزشکی و بهداشت نظامی</title_fa>
<short_title>Paramedical Sciences and Military Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jps.ajaums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2423-7507</journal_id_issn>
<journal_id_issn_online>2538-3086</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/acadpub.JPSMH</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>19</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی و مقایسه توزیع دز حاصل از الگوریتم 10 TMR و شبیه‌سازی مونت‌کارلو در طراحی درمان گامانایف با استفاده از یک فانتوم ناهمگن</title_fa>
	<title>Evaluation and Comparison of Dose Distribution by TMR10 Algorithm and Monte Carlo Simulation in Gamma Knife Treatment Planning Using a Heterogeneous Phantom</title>
	<subject_fa>مقالات کامل</subject_fa>
	<subject>full articles</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:IRANyekan;&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;مقدمه:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt; ﺳﺮﻃﺎﻥ ﺑﻌﺪ ﺍﺯ بیمارهای ﻗﻠﺒﻲ، ﻋﺮﻭﻗﻲ ﺩﻭﻣﻴﻦ ﻋﺎﻣﻞ ﺷﺎﻳﻊ ﻣﺮﮒ ﻭ ﻣﻴﺮ ﺑﻪ ﺷﻤﺎﺭ می&#8204;رود&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;پرتودرمانی شامل کاربرد کنترل&#8204;شده پرتوهای یونیزان (اشعه ایکس، گاما یا ذرات) برای تخریب سلول&#8204;های سرطانی از طریق آسیب به &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;DNA&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;آنهاست، در حالی که بافت&#8204;های سالم اطراف محافظت می&#8204;شوند&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt; گامانایف یک دستگاه استریوتاکتیک رادیوسرجری &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;(SRS)&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;است که دقت بالایی در درمان تومورهای مغزی دارد. وجود ناهمگنی های بافتی می تواند باعث ایجاد تغییراتی در توزیع دز ناحیه ی هدف شود که ممکن است در الگوریتم &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;10&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;TMR&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;سیستم طراحی درمان گامانایف نادیده گرفته شود. بنابراین مقایسه توزیع دز حاصل از سیستم طراحی درمان گامانایف با روش هایی مانند شبیه سازی مونت کارلو که دقت بسیار بالایی دارند می تواند در دقت طراحی درمان اهمیت داشته باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;مواد و روش ها:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt; جهت محاسبه ی توزیع دز ابتدا دستگاه گامانایف مدل &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;ICON&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;با استفاده از کد مونت کارلو&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;MCNPX &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;شبیه سازی شد. پروفایل دز حاصل از شبیه سازی در فانتوم آب محاسبه شد و جهت اعتبار سنجی با پروفایل دز حاصل از فیلم رادیوکرومیک &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;3&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;EBT&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;تابش داده شده با کولیماتور 8 میلی متری دستگاه گامانایف مقایسه شد. پس از اطمینان از صحت اعتبارسنجی&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;،&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt; پروفایل دز شبیه سازی با پروفایل دز الگوریتم &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;10&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;TMR&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;در یک فانتوم ناهمگن سه لایه (معادل استخوان، هوا و بافت نرم) محاسبه و مقایسه شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt; در مقایسه ی منحنی پروفایل دز شبیه سازی و الگوریتم &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;10&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;TMR&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;عدم تطابق هایی مشاهده می شود به گونه ای که در نواحی مرکزی دو منحنی اختلاف کم (کمتر از %1) و با دور شدن از مرکز اختلاف افزایش (تا حدود %7) می یابد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;نتیجه گیری:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt; در مقایسه ی منحنی پروفایل دز شبیه سازی و الگوریتم &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;10&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;TMR&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; mitra=&quot;&quot;&gt;اختلاف مشاهده می شود که این اختلاف به علت یکسان در نظر گرفتن چگالی سر و چگالی آب با یکدیگر و نادیده گرفتن ناهمگنی ها و اختلاف چگالی الکترونی آن ها در این الگوریتم می باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:59.65pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Introduction:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&amp;nbsp;Cancer is the second most common cause of mortality after cardiovascular diseases. Radiotherapy involves the controlled application of ionizing radiation (X-rays, &amp;gamma;-rays, or particles) to destroy cancer cells by damaging their DNA while the surrounding healthy tissues have been protected. Gamma Knife&amp;reg; is a stereotactic radiosurgery (SRS) device with exceptional precision for treating brain tumors. Tissue heterogeneities may cause dose distribution variations in target areas, which could be overlooked by the TMR10 algorithm in Gamma Knife treatment planning. Therefore, comparing dose distributions between Gamma Knife treatment planning systems and high-accuracy methods like Monte Carlo simulation is critical for treatment precision.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:59.65pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&amp;nbsp;To calculate dose distribution, the Gamma Knife&amp;reg; Icon&amp;trade; was first simulated using the MCNPX Monte Carlo code. The simulated dose profile in a water phantom was validated against measurements from EBT3 radiochromic films irradiated with an 8mm collimator. Following validation, simulated dose profiles were compared with TMR10 algorithm-derived profiles in a three-layer heterogeneous phantom (bone, air and soft tissue equivalents).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:59.65pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&amp;nbsp;Discrepancies were observed between Monte Carlo-simulated and TMR10 dose profiles. While central regions showed minimal differences (&lt;1%), peripheral regions exhibited significant deviations (up to 7%).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:59.65pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Discussion and Conclusion: &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;A difference is observed in the comparison of the simulated dose profile curve and the 10TMR algorithm. This difference is due to the fact that the head density and water density are considered the same and the inhomogeneities and differences in their electron densities are ignored in this algorithm.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>ستریوتاکتیک رادیوسرجری (SRS), الگوریتم 10TMR, پروفایل دز, گامانایف مدل ICON</keyword_fa>
	<keyword>Stereotactic radiosurgery (SRS), TMR10 algorithm, Dose profile, Icon Gamma Knife</keyword>
	<start_page>27</start_page>
	<end_page>34</end_page>
	<web_url>http://jps.ajaums.ac.ir/browse.php?a_code=A-10-733-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Soheil</first_name>
	<middle_name></middle_name>
	<last_name>Hassanpour</last_name>
	<suffix></suffix>
	<first_name_fa>سهیل</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسن پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hassanpour.sh90@gmail.com</email>
	<code>10031947532846004311</code>
	<orcid>10031947532846004311</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Radiation, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی هسته ای، مهندسی پرتوپزشکی، واحد تهران مرکزی، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Nooshin</first_name>
	<middle_name></middle_name>
	<last_name>Banaee</last_name>
	<suffix></suffix>
	<first_name_fa>نوشین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بنائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nooshin_banaee@yahoo.com</email>
	<code>10031947532846004312</code>
	<orcid>10031947532846004312</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Medical Radiation, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی هسته ای، مهندسی پرتوپزشکی، واحد تهران مرکزی، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Maryam</first_name>
	<middle_name></middle_name>
	<last_name>Khazaee Moghadam</last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خزاعی مقدم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>maryam.khazaee63@gmail.com</email>
	<code>10031947532846004313</code>
	<orcid>10031947532846004313</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Radiation, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی هسته ای، مهندسی پرتوپزشکی، واحد تهران مرکزی، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mostafa</first_name>
	<middle_name></middle_name>
	<last_name>Yusefi</last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یوسفی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mostafa.u3fi88@gmail.com</email>
	<code>10031947532846004314</code>
	<orcid>10031947532846004314</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Radiation, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی هسته ای، مهندسی پرتوپزشکی، واحد تهران مرکزی، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
