<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Paramedical Sciences and Military Health</title>
<title_fa>علوم پیراپزشکی و بهداشت نظامی</title_fa>
<short_title>Paramedical Sciences and Military Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jps.ajaums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2423-7507</journal_id_issn>
<journal_id_issn_online>2538-3086</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/acadpub.JPSMH</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>18</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی کارایی اسپکت Symbia T با استفاده از شبیه سازی مونت کارلوی SIMIND</title_fa>
	<title>Evaluation of the Performance of Symbia T SPECT Camera Using SIMIND Monte Carlo Simulation</title>
	<subject_fa>مقالات کامل</subject_fa>
	<subject>full articles</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;table align=&quot;center&quot; class=&quot;MsoTableGrid&quot; style=&quot;width:100.0%; border-collapse:collapse; border:none&quot; width=&quot;100%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;border-bottom:1px solid black; width:97%; padding:0cm 7px 0cm 7px; border-top:1px solid black; border-right:none; border-left:none&quot; valign=&quot;top&quot;&gt;
			&lt;h1&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:yekanYW;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;مقدمه:&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; بررسی کیفیت دستگاه اسپکت نقش مهمی&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;در تفسیر و گزارش تصاویر دارد به همین منظور آزمون های ارزیابی کنترل کیفیت برای تعیین عیوب موجود در دستگاه، قبل از تأثیر منفی در تصاویر پزشکی صورت می گیرد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;برای پی بردن به معایب دستگاه، آزمون های کنترل کیفیت و شبیه سازی های متفاوت حیاتی و موثر است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;br&gt;
			&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;مواد و روش ها:&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; در این مطالعه، ابتدا به منظور ارزیابی کیفیت دستگاه، اسپکت&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;Symbia T&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &amp;nbsp;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;با کد مونت کارلوی &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;SIMIND&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; شبیه سازی شده و پارامترهای قدرت تفکیک فضایی و حساسیت مطابق با شرایط تجربی اندازه گیری گردید. سپس نتایج&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;حاصله با نتایج تجربی تحلیل، مقایسه و اعتبار سنجی گردید.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;br&gt;
			&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;یافته ها: &lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;قدرت تفکیک فضایی بصورت شبیه سازی و تجربی در مرکز میدان دید به ترتیب برابر&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;mm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;&amp;nbsp;4/4 و&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;mm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &amp;nbsp;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;73/4 اندازه گیری شد. همچنین حساسیت محاسبه شده بصورت شبیه سازی و تجربی برای پنجره انرژی &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;keV&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; 154-126 برابر&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;cps/MBq&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; 47/98و &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;cps/MBq&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; 46/27 گردید.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; خطای نسبی برای رزولوشن فضایی و حساسیت به ترتیب برابر 7% و 3% شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;br&gt;
			&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;بحث و نتیجه گیری:&lt;/span&gt;&lt;/span&gt;&lt;span b=&quot;&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; خطا بیانگر توافق خوب بین داده های تجربی و شبیه سازی است. با استفاده از این شبیه&#8204;سازی، پارامترهای کنترل کیفیت را می&#8204;توان قبل از انجام آزمایشات تجربی پیش&#8204;بینی کرد. بنابراین، هزینه، ایمنی تابش، الزامات حفاظت و خطا در تصاویر سیستم به طور قابل توجهی به حداقل می رسد. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/h1&gt;
			&lt;br&gt;
			&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:4.0pt&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;border-bottom:1px solid black; width:2%; padding:0cm 7px 0cm 7px; border-top:1px solid black; border-right:none; border-left:none&quot; valign=&quot;top&quot;&gt;&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;b&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;</abstract_fa>
	<abstract>&lt;h2&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;Introduction: The quality control of the SPECT system plays an important role in the interpretation and reporting of images. For this purpose, evaluation tests of quality control are performed to detect problems in the scanner, before the negative impact on medical images. Performing quality control tests and various simulations are vital and effective to determine the defects of the system.&lt;br&gt;
Methods and Materials: In this study, first, the SYMBIA T scanner was simulated with SIMIND Monte Carlo code, and spatial resolution and sensitivity parameters were measured based on experimental conditions. Then, the acquired results were analyzed, compared, and validated with experimental results.&lt;br&gt;
Results: The spatial resolution as experimental and simulation in field of view (FOV) were measured 4.73 mm and 4.4 mm, respectively. Furthermore, the sensitivity calculated by simulation and experiment for 126-154 keV energy windows was equal to 46.27 cps/MBq and 47.98 cps/MBq. The relative errors for spatial resolution and sensitivity were measured 7% and 3%, respectively.&lt;br&gt;
Discussion and Conclusion: The error quantity indicates a good agreement between the experimental and the simulation data. Using this simulation, the quality control parameters can be predicted before performing the experimental quality-control tests. Thus, the cost, radiation safety, shielding requirements and error in the system images are significantly minimized.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/h2&gt;</abstract>
	<keyword_fa>اسپکتSymbia T, کنترل کیفی, ارزیابی, شبیه سازیSIMIND, رزولوشن فضایی, حساسیت</keyword_fa>
	<keyword>SPECT Symbia T, Quality Control, Evaluation, SIMIND Simulation, Spatial Resolution, Sensitivity</keyword>
	<start_page>49</start_page>
	<end_page>56</end_page>
	<web_url>http://jps.ajaums.ac.ir/browse.php?a_code=A-10-622-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Seyedeh Zahra</first_name>
	<middle_name></middle_name>
	<last_name>Islami Rad</last_name>
	<suffix></suffix>
	<first_name_fa>سیده زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اسلامی راد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>szislami@qom.ac.ir</email>
	<code>10031947532846002553</code>
	<orcid>10031947532846002553</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Physics Department, Science Faculty, University of Qom, Qom, Iran</affiliation>
	<affiliation_fa>گروه فیزیک، دانشکده علوم پایه، دانشگاه قم، قم، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Zahra</first_name>
	<middle_name></middle_name>
	<last_name>Safi</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صفی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>zahraseyefi57@gmail.com</email>
	<code>10031947532846002554</code>
	<orcid>10031947532846002554</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Physics Department, Science Faculty, University of Qom, Qom, Iran</affiliation>
	<affiliation_fa>گروه فیزیک، دانشکده علوم پایه، دانشگاه قم، قم، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
