<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Paramedical Sciences and Military Health</title>
<title_fa>علوم پیراپزشکی و بهداشت نظامی</title_fa>
<short_title>Paramedical Sciences and Military Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jps.ajaums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2423-7507</journal_id_issn>
<journal_id_issn_online>2538-3086</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/acadpub.JPSMH</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>برآورد دز موثر اندام های حساس به پرتو ناشی از آزمایشات قفسه سینه، با و بدون سیستم کنترل اکسپوژر اتوماتیک</title_fa>
	<title>Assessment of the Effective Doses for Radiosensitive Organs in Chest CT Scans with or without Using the Automatic Exposure Control System</title>
	<subject_fa>مقالات کامل</subject_fa>
	<subject>full articles</subject>
	<content_type_fa>مروری</content_type_fa>
	<content_type>review</content_type>
	<abstract_fa>&lt;strong&gt;مقدمه:&lt;/strong&gt; روشهای متعددی به منظورکاهش دز از جمله استفاده از سیستم کنترل اتوماتیک اکسپوژر ( AEC ) در تصویربرداریهای سی تی ابداع شده اند. در این مطالعه شاخص دزیمتری سی تی ( CTDI ) بیماران زن در سی تی قفسه سینه، با و بدون سیستم AEC اندازه گیری و دز موثر&amp;nbsp; اندامها برآورد شد.&lt;br&gt;
&lt;strong&gt;مواد و رو شها:&lt;/strong&gt; پارامترهای تابش به 54 بیمار زن مراجعه کننده برای انجام آزمون سی تی قفسه سینه جمع آوری شد. از این تعداد 25 آزمون با سیستم AEC و 29 بیمار بدون AEC انجام شد. CTDI در مرکز و اطراف فانتوم استاندارد اندازه گیری و شاخص وزنی ( CTDIw ) محاسبه، و دز موثر اندام ها با استفاده از نرم افزار محاسبه دز CT Expo برای هر دو گروه محاسبه و مقایسه شد. علاوه بر آن، نویز به عنوان یکی از شاخ صهای کیفیت تصویر در فانتوم آب برای هر دو گروه محاسبه گردید.

&lt;div&gt;&lt;strong&gt;نتایج:&lt;/strong&gt; CTDIw محاسبه شده با استفاده از سیستم کنترل اتوماتیک اکسپوژر، 9/94 میلی گری و دز موثر محاسبه شده 4/ 5 میلی سیورت بود. بدون استفاده از سیستم AEC ، این مقادیر به ترتیب 46 / 12 میلی گری و 3/ 6 میلی سیورت بود. همچنین بیشترین دز موثر دریافتی اندا مها مربوط به پروتکل بدون AEC و اندامهای پستان، مری، ریه و تیموس به ترتیب با میزان 15 ، 14 ، 14 و 14 میلی سیورت بود.&lt;/div&gt;
&lt;strong&gt;بحث و نتیجه گیری:&lt;/strong&gt; اندازه گیریها کاهش دوزی حدود 15 % را هنگام استفاده از AEC نشان می دهد. این در حالی است که نویز از 11 % افزایش خواهد داشت که با توجه به حد استاندارد&amp;nbsp; 5 هانزفیلد یونیت، قابل قبول است. بنابراین استفاده از AEC به منظور کاهش دوز بیمار در سی تی اسکن قفسه سینه زنان، به طور معناداری موثر میباشد.</abstract_fa>
	<abstract>&lt;strong&gt;Introduction:&lt;/strong&gt; There are several techniques for reducing the delivered dose from CT scans such as the automatic exposure control (AEC). This technique regulates the tube current regarding the patient size and weight. The aim of this study was estimation the effective and equivalent dose for radiosensitive organs in women undergoing chest CT scans with or without AEC system using the patient&amp;rsquo;s CT dose index (CTDI) measurements.&lt;br&gt;
&lt;strong&gt;Material and Methods:&lt;/strong&gt; Exposure parameters were gathered from 54 women undergoing chest CT scan. 25 of these scans were performed using AEC and 29 of them were performed without AEC. CTDIs in the center and peripheral regions of the standard phantom were calculated using the exposure parameters. Weighted CTDI was also calculated and effective and equivalent organ doses were obtained using CT-Expo dose calculation software for two mentioned groups. In addition noise was measured for these two groups as an image quality parameter.&lt;br&gt;
&lt;strong&gt;Results:&lt;/strong&gt; Calculated weighted CTDIs were 9.94 mGy and 12.46 mGy using AEC and without using AEC, respectively. The effective doses were calculated based on the ICRP report number 103, and equaled to 5.4 miliSiverts and 6.3 miliSiverts using AEC and without using AEC, respectively. Maximum organ effective doses were 15, 14, 14 and 14 miliSiverts for breast, esophagus, lung and thymus respectively in the non-using AEC system imaging technique.&lt;br&gt;
&lt;strong&gt;Discussion and Conclusion:&lt;/strong&gt; Our measurements indicated a decrease about 15% in dose but an increase about 11.3% in noise using AEC system; however, this increase in noise was in the standard ranges regarding to the standard levels of the Hounsfield unit limits (&amp;plusmn;5 HU). Therefore, it can be concluded that using of AEC was an effective way for dose reduction in women undergoing chest CT.</abstract>
	<keyword_fa>کنترل اتوماتیک اکسپوژر, توموگرافی کامپیوتری, سی تی اسکن قفسه سینه, کاهش دوز</keyword_fa>
	<keyword>Automatic exposure control, Computer Tomography, Chest CT scan, Dose reduction</keyword>
	<start_page>32</start_page>
	<end_page>38</end_page>
	<web_url>http://jps.ajaums.ac.ir/browse.php?a_code=A-10-1-58&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Daryoush Khorramian</first_name>
	<middle_name></middle_name>
	<last_name>Khorramian</last_name>
	<suffix></suffix>
	<first_name_fa>داریوش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خرمیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Daryoushkhoramian@gmail.com</email>
	<code>1003194753284600413</code>
	<orcid>1003194753284600413</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Soroush</first_name>
	<middle_name></middle_name>
	<last_name>Sistani</last_name>
	<suffix></suffix>
	<first_name_fa>سروش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیستانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600414</code>
	<orcid>1003194753284600414</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشگاه علوم پزشکی سمنان، سمنان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Elahi</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>الهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600415</code>
	<orcid>1003194753284600415</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Salar</first_name>
	<middle_name></middle_name>
	<last_name>Bijari</last_name>
	<suffix></suffix>
	<first_name_fa>سالار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیجاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600416</code>
	<orcid>1003194753284600416</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
